Category: | Nylon 6 , Polyamide 6 |
Manufacturer: | LANXESS GmbH |
Trademark: | Durethan® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | znoUC6_DurethanBKV30H30000000.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
PA 6, 30 % glass fibers, injection molding, heat-aging stabilized |
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
Agency Ratings |
|
Processing Method |
|
Multi-Point Data |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density (23°C) | 1.36 | -- | g/cm³ | ISO 1183 |
Apparent Density | 0.70 | -- | g/cm³ | ISO 60 |
Molding Shrinkage | ISO 294-4 | |||
Vertical flow direction : 280°C, 2.00mm 1 | 0.69 | -- | % | ISO 294-4 |
Vertical flow direction : 120°C, 2 hours, 2.00mm 2 | 0.12 | -- | % | ISO 294-4 |
Flow direction : 280°C, 2.00mm 3 | 0.24 | -- | % | ISO 294-4 |
Flow direction : 120°C, 2 hours, 2.00mm 4 | 0.070 | -- | % | ISO 294-4 |
Water Absorption | ISO 62 | |||
Saturated, 23°C | 7.0 | -- | % | ISO 62 |
Equilibrium, 23°C, 50% RH | 2.1 | -- | % | ISO 62 |
Hardness | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Ball Indentation Hardness | 210 | 100 | MPa | ISO 2039-1 |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Modulus (23°C) | 9800 | 6100 | MPa | ISO 527-2/1 |
Tensile Stress (Break, 23°C) | 180 | 105 | MPa | ISO 527-2/5 |
Tensile Strain (Break, 23°C) | 3.0 | 6.0 | % | ISO 527-2/5 |
Tensile Creep Modulus | ISO 899-1 | |||
1 hr | -- | 5100 | MPa | ISO 899-1 |
1000 hr | -- | 4100 | MPa | ISO 899-1 |
Flexural Modulus 5(23°C) | 8600 | 5100 | MPa | ISO 178/A |
Flexural Stress 6 | ||||
3.5% strain | -- | 145 | MPa | ISO 178/A |
23°C | 280 | 170 | MPa | ISO 178 |
Flexural Strain at Flexural Strength 7(23°C) | 4.0 | 6.0 | % |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Burning Behavior 8 | passed | -- | ISO 3795 |
Additional Information | Dry | Conditioned | Test Method | |
---|---|---|---|---|
ISO Shortname | PA 6, GHR, 14-100, GF30 | -- | ISO 1874 |
Injection | Dry | Unit | Test Method |
---|---|---|---|
Residual Moisture Content | 0.030 - 0.12 | % | Karl Fisher |
Films | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Film Puncture Energy | ISO 6603-2 | |||
-- 9 | 6.00 | 5.00 | J | ISO 6603-2 |
-- 10 | 8.00 | 14.0 | J | ISO 6603-2 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | |||
-30°C | 10 | 10 | kJ/m² | ISO 179/1eA |
23°C | 15 | 20 | kJ/m² | ISO 179/1eA |
Charpy Unnotched Impact Strength | ISO 179/1eU | |||
-30°C | 70 | 70 | kJ/m² | ISO 179/1eU |
23°C | 80 | 95 | kJ/m² | ISO 179/1eU |
Notched Izod Impact | ISO 180/1A | |||
-30°C | 10 | 10 | kJ/m² | ISO 180/1A |
23°C | 15 | 20 | kJ/m² | ISO 180/1A |
Unnotched Izod Impact Strength | ISO 180/1U | |||
-30°C | 70 | 80 | kJ/m² | ISO 180/1U |
23°C | 75 | 85 | kJ/m² | ISO 180/1U |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature | ||||
0.45 MPa, not annealed | 215 | -- | °C | ISO 75-2/B |
1.8 MPa, not annealed | 200 | -- | °C | ISO 75-2/A |
8.0 MPa, not annealed | 110 | -- | °C | ISO 75-2/C |
Vicat Softening Temperature | ||||
-- | 200 | -- | °C | ISO 306/B50 |
-- | > 200 | -- | °C | ISO 306/B120 |
Melting Temperature 11 | 222 | -- | °C | ISO 11357-3 |
Linear thermal expansion coefficient | ISO 11359-2 | |||
Flow : 23 to 55°C | 2.0E-5 | -- | cm/cm/°C | ISO 11359-2 |
Lateral : 23 to 55°C | 8.0E-5 | -- | cm/cm/°C | ISO 11359-2 |
Electrical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Surface Resistivity | 1.0E+14 | 1.0E+12 | ohms | IEC 60093 |
Volume Resistivity (23°C) | 1.0E+15 | 1.0E+12 | ohms·cm | IEC 60093 |
Dielectric Strength (23°C, 1.00 mm) | 40 | 35 | kV/mm | IEC 60243-1 |
Relative Permittivity | IEC 60250 | |||
23°C, 100 Hz | 4.00 | 15.0 | IEC 60250 | |
23°C, 1 MHz | 4.00 | 5.00 | IEC 60250 | |
Comparative Tracking Index (Solution A) | 525 | -- | V | IEC 60112 |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Flame Rating | UL 94 | |||
-- | HB | -- | UL 94 | |
1.60 mm | HB | -- | UL 94 | |
Glow Wire Flammability Index | IEC 60695-2-12 | |||
0.800 mm | 700 | -- | °C | IEC 60695-2-12 |
1.60 mm | 700 | -- | °C | IEC 60695-2-12 |
3.00 mm | 700 | -- | °C | IEC 60695-2-12 |
Oxygen Index 12 | 22 | -- | % | ISO 4589-2 |
Injection | Dry | Unit | Test Method |
---|---|---|---|
Drying Temperature - Dry Air Dryer | 80.0 | °C | |
Drying Time - Dry Air Dryer | 2.0 - 6.0 | hr | |
Processing (Melt) Temp | 270 - 290 | °C | |
Mold Temperature | 80.0 - 120 | °C |
Note Message | |
---|---|
1 . | 60x60x2; MT 80°C; 600 Bar |
2 . | 60x60x2 |
3 . | 60x60x2; MT 80°C; 600 Bar |
4 . | 60x60x2 |
5 . | 2.0 mm/min |
6 . | 2.0 mm/min |
7 . | Pull Rate: 2 mm/min; 50% RH |
8 . | US-FMVSS302 |
9 . | -30°C |
10 . | 23°C |
11 . | 10°C/min |
12 . | Procedure A |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
RTP 4081 AR 10 TFE 20 SI 2 | RTP Company | PPA | RTP |
Spartech Polycom SC7-7006U | Spartech Polycom | PC | Spartech |
ASPUN™ 6835A | The Dow Chemical Company | LLDPE | ASPUN™ |
Complet® LGF30-PA6 | PlastiComp, Inc. | Nylon 6 | Complet® |
EL-Lene™ H255JA | SCG Chemicals Co., Ltd. | HDPE | EL-Lene™ |