XANTAR® LDS 3734

Category: PC , Polycarbonate
Manufacturer: Mitsubishi Engineering-Plastics Corp
Trademark: XANTAR® LDS
Fillers: -
Ports: Qinzhou, Shekou, Shanghai, Ningbo
Delivery Terms FOB, CIF, DAP, DAT, DDP
PDF: wLkWXT_XANTAR-LDS-3734.pdf
PRICE: ​Order Products​ email   sales@su-jiao.com
Wechat: WECHAT
Message
Laser Direct Structuring (LDS)*, Flame Retardant (Halogen free), Impact Modified

*The compound is intended specifically for the use in the process of manufacturing conducting path designs according to the German application of the patent 101 32 092 of LPKF Laser & Electronics AG. Please address straight to LPKF Laser & Electronics AG (www.LPKF.de).
General Information
Additive
  • Flame Retardant
  • Impact Modifier
Features
  • Flame Retardant
  • Halogen Free
  • Impact Modified
Forms
  • Pellets
PhysicalNominal ValueUnitTest Method
Density 1.29g/cm³ISO 1183
Melt Mass-Flow Rate (MFR) (260°C/5.0 kg)11g/10 minISO 1133
Molding Shrinkage - Flow 0.60%ISO 294-4
Water Absorption (Equilibrium, 23°C, 50% RH)0.35%ISO 62
MechanicalNominal ValueUnitTest Method
Tensile Modulus 2200MPaISO 527-2
Tensile Stress (Yield)50.0MPaISO 527-2
Tensile Strain (Yield)6.0%ISO 527-2
Nominal Tensile Strain at Break > 50%ISO 527-2
Flexural Modulus 2000MPaISO 178
Flexural Stress 78.0MPaISO 178
ImpactNominal ValueUnitTest Method
Charpy Notched Impact Strength ISO 179/1eA
    -30°C 25kJ/m²
    23°C 45kJ/m²
Charpy Unnotched Impact Strength ISO 179/1eU
    -30°C No Break
    23°C No Break
Notched Izod Impact Strength ISO 180/4A
    -20°C 35kJ/m²
    23°C 50kJ/m²
Multi-Axial Instrumented Impact Energy
    -20°C 125.0JInternal Method
    23°C 40.0JISO 6603-2
    23°C 225.0JInternal Method
ThermalNominal ValueUnitTest Method
Heat Deflection Temperature (1.8 MPa, Unannealed)120°CISO 75-2/A
Vicat Softening Temperature 142°CISO 306/B50
CLTE ISO 11359-2
    Flow 6.0E-5cm/cm/°C
    Transverse 6.0E-5cm/cm/°C
ElectricalNominal ValueUnitTest Method
Surface Resistivity > 1.0E+15ohmsIEC 60093
Volume Resistivity > 1.0E+15ohms·cmIEC 60093
Relative Permittivity (1.00 GHz)3.10IEC 60250
Dissipation Factor (1.00 GHz)6.0E-3IEC 60250
FlammabilityNominal ValueUnitTest Method
Flammability Classification (0.400 mm)HBIEC 60695-11-10, -20
Note Message
1 .Part with rib, Based on ISO 6603-2
2 .Part with rib, Based on ISO 6603-2
Resin Grade Manufacturer Category Trademark
SCHULAMID® 6 NV 12 FR A. Schulman Europe Nylon 6 SCHULAMID®
Sylvin 2910-50 Clear Sylvin Technologies Incorporated PVC, Unspecified Sylvin
Zytel庐 HTN FR52G30BL BK337 DuPont Performance Polymers PPA Zytel® HTN
ACCUTECH™ CP0437G10CL ACLO Compounders Inc. PP Copolymer ACCUTECH™
CoolPoly® D3610 Celanese Corporation Nylon 66/6 CoolPoly®