Category: | PBT , Polybutylene Terephthalate |
Manufacturer: | LANXESS Corporation |
Trademark: | POCAN® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | ozpaih_POCANBF4215000000.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
PBT, 12 % glass fibers, injection molding, flame retardant |
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density (23°C) | 1.53 | g/cm³ | ISO 1183 |
Apparent Density | 0.80 | g/cm³ | ISO 60 |
Melt Volume-Flow Rate (MVR) (260°C/2.16 kg) | 21.0 | cm³/10min | ISO 1133 |
Molding Shrinkage | ISO 2577 | ||
Vertical flow direction : 250°C, 2.00mm 1 | 1.1 | % | ISO 2577 |
Vertical flow direction : 120°C, 4 hours, 2.00mm 2 | 0.10 | % | ISO 2577 |
Flow direction : 250°C, 2.00mm 3 | 0.80 | % | ISO 2577 |
Flow direction : 120°C, 4 hours, 2.00mm 4 | 0.10 | % | ISO 2577 |
Water Absorption | ISO 62 | ||
Saturated, 23°C | 0.30 | % | ISO 62 |
Equilibrium, 23°C, 50% RH | 0.10 | % | ISO 62 |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Ball Indentation Hardness | 180 | MPa | ISO 2039-1 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus (23°C) | 6000 | MPa | ISO 527-2/1 |
Tensile Stress (Break, 23°C) | 100 | MPa | ISO 527-2/5 |
Tensile Strain (Break, 23°C) | 2.5 | % | ISO 527-2/5 |
Tensile Creep Modulus | ISO 899-1 | ||
1 hr | 5500 | MPa | ISO 899-1 |
1000 hr | 5000 | MPa | ISO 899-1 |
Flexural Modulus 5(23°C) | 5700 | MPa | ISO 178/A |
Flexural Stress 6(23°C) | 155 | MPa | ISO 178/A |
Flexural Strain at Flexural Strength (23°C) 7 | 3.2 | % | ISO 178/A |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Halving Interval | IEC 60216 | ||
Electric Strength | 12.4 | °C | IEC 60216 |
Tensile Impact Strength | 9.2 | °C | IEC 60216 |
Tensile Strength | 11.7 | °C | IEC 60216 |
Temperature index | IEC 60216 | ||
Electric Strength, 20000 hr | 145 | °C | IEC 60216 |
Tensile Impact Strength, 20000 hr | 135 | °C | IEC 60216 |
Tensile Strength, 20000 hr | 140 | °C | IEC 60216 |
Additional Information | Nominal Value | Test Method | |
---|---|---|---|
Electrolytical Corrosion (23°C) | A 1 | IEC 60426 | |
ISO Shortname | PBT, GFHMR, 09-060, GF12; ISO 1043-PBT GF FR (17) | ISO 7792 |
Injection | Nominal Value | Unit | Test Method |
---|---|---|---|
Residual Moisture Content | 0.0 - 0.020 | % | Karl Fisher |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | ||
-30°C | < 10 | kJ/m² | ISO 179/1eA |
23°C | < 10 | kJ/m² | ISO 179/1eA |
Charpy Unnotched Impact Strength | ISO 179/1eU | ||
-30°C | 25 | kJ/m² | ISO 179/1eU |
23°C | 25 | kJ/m² | ISO 179/1eU |
Notched Izod Impact | ISO 180/1A | ||
-40°C | < 10 | kJ/m² | ISO 180/1A |
-30°C | < 10 | kJ/m² | ISO 180/1A |
23°C | < 10 | kJ/m² | ISO 180/1A |
Unnotched Izod Impact Strength | ISO 180/1U | ||
-30°C | 20 | kJ/m² | ISO 180/1U |
23°C | 20 | kJ/m² | ISO 180/1U |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Heat Deflection Temperature | |||
0.45 MPa, not annealed | 210 | °C | ISO 75-2/B |
1.8 MPa, not annealed | 185 | °C | ISO 75-2/A |
Vicat Softening Temperature | 205 | °C | ISO 306/B120 |
Ball Pressure Test (205°C) | Pass | IEC 60695-10-2 | |
Melting Temperature 8 | 225 | °C | ISO 11357-3 |
Linear thermal expansion coefficient | ISO 11359-2 | ||
Flow : 23 to 55°C | 4.0E-5 | cm/cm/°C | ISO 11359-2 |
Lateral : 23 to 55°C | 1.0E-4 | cm/cm/°C | ISO 11359-2 |
Thermal Conductivity (23°C) | 0.20 | W/m/K | ISO 8302 |
RTI Elec | 130 | °C | UL 746 |
RTI Imp | 130 | °C | UL 746 |
RTI | 140 | °C | UL 746 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Surface Resistivity | > 1.0E+15 | ohms | IEC 60093 |
Volume Resistivity (23°C) | > 1.0E+13 | ohms·cm | IEC 60093 |
Dielectric Strength (23°C, 1.00 mm) | 29 | kV/mm | IEC 60243-1 |
Relative Permittivity | IEC 60250 | ||
23°C, 100 Hz | 3.60 | IEC 60250 | |
23°C, 1 MHz | 3.40 | IEC 60250 | |
Dissipation Factor | IEC 60250 | ||
23°C, 100 Hz | 4.0E-3 | IEC 60250 | |
23°C, 1 MHz | 0.019 | IEC 60250 | |
Comparative Tracking Index (CTI) | PLC 3 | UL 746 | |
Comparative Tracking Index (Solution A) | 200 | V | IEC 60112 |
High Amp Arc Ignition (HAI) | PLC 0 PLC 0 PLC 0 | UL 746 | |
Hot-wire Ignition (HWI) | PLC 2 PLC 3 PLC 4 | UL 746 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flame Rating (0.400 mm) | V-0 | UL 94 | |
Glow Wire Flammability Index | IEC 60695-2-12 | ||
0.800 mm | 960 | °C | IEC 60695-2-12 |
1.50 mm | 960 | °C | IEC 60695-2-12 |
3.00 mm | 960 | °C | IEC 60695-2-12 |
Glow Wire Ignition Temperature | IEC 60695-2-13 | ||
0.750 mm | 700 | °C | IEC 60695-2-13 |
1.50 mm | 700 | °C | IEC 60695-2-13 |
3.00 mm | 700 | °C | IEC 60695-2-13 |
Oxygen Index 9 | 32 | % | ISO 4589-2 |
Injection | Nominal Value | Unit | Test Method |
---|---|---|---|
Drying Temperature - Circulation Dryer | 120 | °C | |
Drying Time - Circulation Dryer | 4.0 - 8.0 | hr | |
Processing (Melt) Temp | 240 - 260 | °C | |
Mold Temperature | 80.0 - 100 | °C |
Note Message | |
---|---|
1 . | 60x60x2mm, 80°C MT, 600 bar |
2 . | 60x60x2mm |
3 . | 60x60x2mm, 80°C MT, 600 bar |
4 . | 60x60x2mm |
5 . | 2.0 mm/min |
6 . | 2.0 mm/min |
7 . | 2 mm/min |
8 . | 10°C/min |
9 . | Procedure A |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Telcar® TL-1336B | Teknor Apex Company | TPE | Telcar® |
VITAMIDE® TH36BK6752 | Jackdaw Polymers | Nylon 66/6 | VITAMIDE® |
Elvax® 3135X | DuPont Packaging & Industrial Polymers | EVA | Elvax® |
KumhoSunny AES HW600G | Shanghai KumhoSunny Plastics Co., Ltd. | AES | KumhoSunny AES |
Polene LDPE D 2024 | TPI Polene Public Company Limited | LDPE | Polene LDPE |