Grilamid® XE 3997 nat

Category: Nylon 12 , Polyamide 12
Manufacturer: EMS-GRIVORY
Trademark: Grilamid®
Fillers: -
Ports: Qinzhou, Shekou, Shanghai, Ningbo
Delivery Terms FOB, CIF, DAP, DAT, DDP
PDF: osonY4_Grilamid-XE-3997-nat.pdf
PRICE: ​Order Products​ email   sales@su-jiao.com
Wechat: WECHAT
Message
Grilamid® XE 3997 nat is a Polyamide 12 (Nylon 12) material. It is available in Africa & Middle East, Asia Pacific, Europe, Latin America, or North America for blow molding, extrusion, or injection stretch blow molding.

Important attributes of Grilamid® XE 3997 nat are:
  • Flame Rated
  • RoHS Compliant
  • Food Contact Acceptable

Typical applications include:
  • Food Contact Applications
  • Containers
  • Medical/Healthcare
  • Packaging
General Information
Features
  • Food Contact Acceptable
Uses
  • Blow Molding Applications
  • Blown Containers
  • Medical/Healthcare Applications
  • Packaging
Agency Ratings
  • EU Food Contact, Unspecified Rating
  • FDA Food Contact, Unspecified Rating
RoHS Compliance
  • RoHS Compliant
Appearance
  • Clear/Transparent
  • Natural Color
Forms
  • Granules
Processing Method
  • Blow Molding
  • Extrusion
  • Injection Stretch Blow Molding
PhysicalDryConditionedUnitTest Method
Density 1.00--g/cm³ISO 1183
Molding Shrinkage ISO 294-4
     Across Flow 0.80--%
     Flow 0.70--%
Water Absorption ISO 62
     Saturation, 23°C 3.0--%
     Equilibrium, 23°C, 50% RH 1.5--%
HardnessDryConditionedUnitTest Method
Ball Indentation Hardness --90.0MPaISO 2039-1
MechanicalDryConditionedUnitTest Method
Tensile Modulus --1600MPaISO 527-2
Tensile Stress ISO 527-2
     Yield --60.0MPa
     Break --45.0MPa
Tensile Strain ISO 527-2
     Yield --6.0%
     Break --> 50%
Nominal Tensile Strain at Break --> 50%ISO 527-2
ImpactDryConditionedUnitTest Method
Charpy Notched Impact Strength ISO 179/1eA
     -30°C --12kJ/m²
     23°C --13kJ/m²
Charpy Unnotched Impact Strength ISO 179/1eU
     -30°C --No Break
     23°C --No Break
ThermalDryConditionedUnitTest Method
Heat Deflection Temperature
     0.45 MPa, Unannealed 135--°CISO 75-2/B
     1.8 MPa, Unannealed 115--°CISO 75-2/A
Continuous Use Temperature Internal Method
     -- 180.0 to 100--°C
     -- 2120--°C
Glass Transition Temperature 3155--°CISO 11357-2
CLTE ISO 11359-2
     Flow 9.0E-5--cm/cm/°C
     Transverse 9.0E-5--cm/cm/°C
ElectricalDryConditionedUnitTest Method
Surface Resistivity --1.0E+12ohmsIEC 60093
Volume Resistivity --1.0E+13ohms·cmIEC 60093
Electric Strength --34kV/mmIEC 60243-1
Comparative Tracking Index --600VIEC 60112
FlammabilityDryConditionedUnitTest Method
Flammability Classification (0.800 mm)HB--IEC 60695-11-10, -20
Additional InformationDryConditionedTest Method
ISO Type PA MACM12, GT, 14-020--ISO 1874
Note Message
1 .Long Term
2 .Short Term
3 .10°C/min
Resin Grade Manufacturer Category Trademark
RTP 1300 C TFE 20 RTP Company PPS RTP
POLYVIN® PVC 6620 A. Schulman Inc. PVC, Unspecified POLYVIN®
Vital-Line SHE6000 Teknor Apex Asia Pacific PTE. LTD. PVC, Flexible Vital-Line
Electrafil® J-50/CF/10 Techmer Engineered Solutions PC Electrafil®
MACOMASS TPE MM-TPE-V 5050 MACOMASS Verkaufs AG TPE MACOMASS TPE