Category: | Nylon 66 , Polyamide 66 |
Manufacturer: | Nilit Plastics |
Trademark: | FRIANYL® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | lrgNOk_FRIANYL-A3-H-GF25-V0.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
FRIANYL® A3 H GF25 V0 is a Polyamide 66 (Nylon 66) compound, 25% glass fiber reinforced, heat stabilized, flame retardant, halogen and red phosphorous free, UL listed V0. It is certified according to railways requirements NFF 16-101. This compound is intended for injection molding. FRIANYL® A3 H GF25 V0 is primarily designed for the Electrical and Electronic industry. It is also suitable for Automotive or Industrial & Consumer applications. |
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
Uses |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density (23°C) | 1.36 | g/cm³ | ISO 1183 |
Molding Shrinkage | ISO 294-4 | ||
Across Flow : 23°C | 0.50 | % | |
Flow : 23°C | 0.30 | % | |
Water Absorption | ISO 62 | ||
23°C, 24 hr | 0.80 | % | |
Saturation, 23°C | 5.0 | % |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus (23°C) | 8500 | MPa | ISO 527-2 |
Tensile Stress (Yield, 23°C) | 150 | MPa | ISO 527-2 |
Tensile Strain (Break, 23°C) | 3.3 | % | ISO 527-2 |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | ||
-30°C | 8.5 | kJ/m² | |
23°C | 9.5 | kJ/m² | |
Charpy Unnotched Impact Strength | ISO 179/1eU | ||
23°C | 55 | kJ/m² | |
30°C | 47 | kJ/m² | |
Notched Izod Impact Strength | ISO 180/A | ||
-30°C | 7.5 | kJ/m² | |
23°C | 9.0 | kJ/m² |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Heat Deflection Temperature | |||
0.45 MPa, Unannealed | 255 | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 245 | °C | ISO 75-2/A |
Continuous Use Temperature 1 | 140 | °C | IEC 60216 |
Ball Pressure Test | IEC 60695-10-2 | ||
125°C | Pass | ||
165°C | Pass |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Surface Resistivity 2 | 1.0E+13 | ohms | IEC 60093 |
Volume Resistivity (23°C) | 1.0E+15 | ohms·cm | IEC 60093 |
Electric Strength (2.00 mm) | 21 | kV/mm | IEC 60243-1 |
Comparative Tracking Index (3.20 mm, Solution A) | 600 | V | IEC 60112 |
Needle Flame Test | IEC 60695-11-5 | ||
1.00 mm | Pass | ||
2.00 mm | Pass |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flame Rating | UL 94 | ||
0.400 mm | V-0 | ||
0.800 mm | V-0 | ||
1.60 mm | V-0 | ||
3.20 mm | V-0 | ||
Glow Wire Flammability Index | IEC 60695-2-12 | ||
0.800 mm | 960 | °C | |
3.20 mm | 960 | °C | |
Glow Wire Ignition Temperature | IEC 60695-2-13 | ||
0.800 mm | 775 | °C | |
3.20 mm | 800 | °C | |
Oxygen Index | 36 | % | ISO 4589-2 |
Flammability 3 | SE | FMVSS 302 |
Note Message | |
---|---|
1 . | 20000 hr |
2 . | 23°C |
3 . | 355x100x1mm |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Marlex® 1007 | Chevron Phillips Chemical Company LLC | LDPE | Marlex® |
Promyde® B30 P2 G30 | NUREL, S.A. | Nylon 6 | Promyde® |
RJM SN602-NH | RJM International, Inc. | Nylon 66 | RJM |
BorSafe™ HE3494-LS-H | Borealis AG | HDPE | BorSafe™ |
Hostacom EKC 265N 2 C12594 | LyondellBasell Industries | PP Copolymer | Hostacom |