Category: | Nylon 66 , Polyamide 66 |
Manufacturer: | Nilit Plastics |
Trademark: | NILAMID® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | lXxVUn_NILAMID-A3-J10-GF30.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
NILAMID® A3 J10 GF30 is a Polyamide 66 (Nylon 66) compound, 30% glass fiber reinforced, impact modified. This compound is intended for injection molding. NILAMID® A3 J10 GF30 is primarily designed for the Automotive industry. It is also suitable for Industrial & Consumer applications. |
General Information | |
---|---|
Filler / Reinforcement |
|
Features |
|
Uses |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density (23°C) | 1.30 | g/cm³ | ISO 1183 |
Molding Shrinkage | ISO 294-4 | ||
Across Flow : 23°C | 0.50 | % | |
Flow : 23°C | 0.30 | % | |
Water Absorption | ISO 62 | ||
23°C, 24 hr | 0.60 | % | |
Saturation, 23°C | 4.5 | % |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus (23°C) | 8300 | MPa | ISO 527-2 |
Tensile Stress (Yield, 23°C) | 140 | MPa | ISO 527-2 |
Tensile Strain (Break, 23°C) | 3.5 | % | ISO 527-2 |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | ||
-30°C | 14 | kJ/m² | |
23°C | 20 | kJ/m² | |
Charpy Unnotched Impact Strength | ISO 179/1eU | ||
23°C | 55 | kJ/m² | |
30°C | 45 | kJ/m² | |
Notched Izod Impact Strength | ISO 180/A | ||
-30°C | 13 | kJ/m² | |
23°C | 19 | kJ/m² |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Heat Deflection Temperature | |||
0.45 MPa, Unannealed | 250 | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 240 | °C | ISO 75-2/A |
Continuous Use Temperature 1 | 105 | °C | IEC 60216 |
Ball Pressure Test | IEC 60695-10-2 | ||
125°C | Pass | ||
165°C | Pass |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Surface Resistivity 2 | 1.0E+12 | ohms | IEC 60093 |
Volume Resistivity (23°C) | 1.0E+15 | ohms·cm | IEC 60093 |
Electric Strength (2.00 mm) | 21 | kV/mm | IEC 60243-1 |
Comparative Tracking Index (3.20 mm, Solution A) | 550 | V | IEC 60112 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flame Rating | UL 94 | ||
0.800 mm | HB | ||
1.60 mm | HB | ||
3.20 mm | HB | ||
Glow Wire Flammability Index | IEC 60695-2-12 | ||
0.800 mm | 650 | °C | |
3.20 mm | 650 | °C | |
Oxygen Index | 21 | % | ISO 4589-2 |
Note Message | |
---|---|
1 . | 20000 hr |
2 . | 23°C |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
TPX® RT18XB | Mitsui Chemicals America, Inc. | PMP Copolymer | TPX® |
Capilene® G 86 E | Carmel Olefins Ltd. | PP Homopolymer | Capilene® |
Karina MBU BROWN(PI) -E 36/ 59-IE-HSF | Karina Ind. e Com. de Plásticos Ltda | PVC, Unspecified | Karina |
POCAN® B 1701 000000 | LANXESS Corporation | PBT | POCAN® |
Osterlene® HIPS03.503 | Osterman & Company | PS (HIPS) | Osterlene® |