Category: | Nylon 66 , Polyamide 66 |
Manufacturer: | A. Schulman Europe |
Trademark: | SCHULAMID® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | lITKRs_SCHULAMID-66-GBF-3020.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
30% glass fiber and glass bead reinforced Polyamide 66 with high tensile strength and dimensional stability |
General Information | |
---|---|
Filler / Reinforcement |
|
Features |
|
Processing Method |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density | 1.35 | -- | g/cm³ | ISO 1183/A |
Water Absorption (Saturation, 23°C) | 2.0 | -- | % | ISO 62 |
Viscosity Number | 145 | -- | cm³/g | ISO 307 |
Hardness | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Ball Indentation Hardness (H 358/30) | 220 | 140 | MPa | ISO 2039-1 |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Modulus | 7600 | 4400 | MPa | ISO 527-2/1A/1 |
Tensile Stress (Break) | 130 | 80.0 | MPa | ISO 527-2/1A/5 |
Tensile Strain (Break) | 3.0 | 10 | % | ISO 527-2/1A/5 |
Flexural Modulus 1 | 6000 | -- | MPa | ISO 178 |
Flexural Stress 2 | 190 | -- | MPa | ISO 178 |
Flexural Strain at Flexural Strength | 4.5 | -- | % | ISO 178 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | |||
-30°C | 6.0 | -- | kJ/m² | |
23°C | 14 | 18 | kJ/m² | |
Charpy Unnotched Impact Strength | ISO 179/1eU | |||
-30°C | 35 | -- | kJ/m² | |
23°C | 40 | 60 | kJ/m² |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature | ||||
0.45 MPa, Unannealed | 245 | -- | °C | ISO 75-2/Bf |
1.8 MPa, Unannealed | 245 | -- | °C | ISO 75-2/Af |
Vicat Softening Temperature | ||||
-- | 240 | -- | °C | ISO 306/A50 |
-- | 235 | -- | °C | ISO 306/B50 |
Ball Pressure Test (140°C) | Pass | -- | IEC 60695-10-2 |
Electrical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Surface Resistivity | > 1.0E+15 | > 1.0E+12 | ohms | IEC 60093 |
Volume Resistivity | > 1.0E+13 | > 1.0E+10 | ohms·cm | IEC 60093 |
Comparative Tracking Index | 450 | -- | V | IEC 60112 |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Burning Rate | < 100 | -- | mm/min | ISO 3795 |
Flammability Classification | IEC 60695-11-10, -20 | |||
1.50 mm | HB | -- | ||
3.00 mm | HB | -- | ||
Glow Wire Flammability Index | IEC 60695-2-12 | |||
1.50 mm | -- | 650 | °C | |
3.00 mm | -- | 650 | °C |
Note Message | |
---|---|
1 . | 2.0 mm/min |
2 . | 2.0 mm/min |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
RTP 200 FR TFE 15 | RTP Company | Nylon 66 | RTP |
MIRASON™ C-2494 | Mitsui Chemicals, Inc. | LDPE | MIRASON™ |
Styrolution PS 145D | INEOS Styrolution Group GmbH | PS (GPPS) | Styrolution PS |
Acrigel® ECP800 | Unigel Plásticos | Acrylic (PMMA) | Acrigel® |
Flexathene® TP4308HR | LyondellBasell Industries | Polyolefin, Unspecified | Flexathene® |