Category: | PARA , Polyarylamide |
Manufacturer: | Mitsubishi Engineering-Plastics Corp |
Trademark: | Reny® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | g4muVL_Reny-NXG5945S.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Reny® NXG5945S is a Polyarylamide (PARA) material filled with 45% glass fiber. It is available in Asia Pacific, Europe, or North America for injection molding. Primary attribute of Reny® NXG5945S: Flame Rated. |
General Information | |
---|---|
Filler / Reinforcement |
|
Processing Method |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density | 1.52 | -- | g/cm³ | ISO 1183 |
Melt Mass-Flow Rate (MFR) (280°C/5.0 kg) | 13 | -- | g/10 min | ISO 1133 |
Melt Volume-Flow Rate (MVR) (280°C/5.0 kg) | 8.50 | -- | cm³/10min | ISO 1133 |
Molding Shrinkage | 0.32 | -- | % | |
Water Absorption (Equilibrium, 23°C, 50% RH) | 0.73 | -- | % | ISO 62 |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Modulus | 16000 | 15400 | MPa | ISO 527-2 |
Tensile Stress (Break) | 208 | 202 | MPa | ISO 527-2 |
Tensile Strain (Break) | 2.0 | 2.2 | % | ISO 527-2 |
Flexural Modulus | 14300 | 14000 | MPa | ISO 178 |
Flexural Stress | 349 | 315 | MPa | ISO 178 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Notched Impact Strength (23°C) | 15 | 14 | kJ/m² | ISO 179 |
Charpy Unnotched Impact Strength (23°C) | 90 | 77 | kJ/m² | ISO 179 |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature (1.8 MPa, Unannealed) | 232 | -- | °C | ISO 75-2/A |
Glass Transition Temperature | 87.0 | -- | °C | ISO 11357-2 |
Melting Temperature | 257 | -- | °C | ISO 11357-3 |
CLTE | ISO 11359-2 | |||
Flow | 1.1E-5 | -- | cm/cm/°C | |
Transverse | 5.6E-5 | -- | cm/cm/°C |
Electrical | Dry | Conditioned | Test Method | |
---|---|---|---|---|
Relative Permittivity | IEC 60250 | |||
100 Hz | 4.20 | 4.60 | ||
1 MHz | 4.10 | 4.20 | ||
Dissipation Factor | IEC 60250 | |||
100 Hz | 5.5E-3 | 0.020 | ||
1 MHz | 6.7E-3 | 0.012 |
Flammability | Dry | Conditioned | Test Method | |
---|---|---|---|---|
Flame Rating (1.60 mm) | HB | -- | UL 94 |
Injection | Dry | Unit | |
---|---|---|---|
Drying Temperature | |||
A | 120 | °C | |
B | 80.0 | °C | |
Drying Time | |||
A | > 3.0 | hr | |
B | > 12 | hr | |
Rear Temperature | 280 | °C | |
Middle Temperature | 285 | °C | |
Front Temperature | 290 | °C | |
Nozzle Temperature | 290 | °C | |
Mold Temperature | 120 to 140 | °C | |
Injection Pressure | 20.0 to 150 | MPa | |
Injection Rate | Moderate-Fast | ||
Screw Speed | 60 to 150 | rpm |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
PRL TP-FR-IM | Polymer Resources Ltd. | PBT | PRL |
Delta N66R-1G70 | Delta Polymers | Nylon 66 | Delta |
Gallonprene® GP410-8202 | Shenzhen Sungallon Rubber & Plastic Corporation Limited | TPE | Gallonprene® |
GETILAN GPE/150 | Crosspolimeri S.p.A. | XLPE | GETILAN |
Karina RED PVC COMPOUND -E 780-42/179-A-IS (C800) | Karina Ind. e Com. de Plásticos Ltda | PVC, Unspecified | Karina |