Category: | Nylon 6 , Polyamide 6 |
Manufacturer: | RTP Company |
Trademark: | RTP |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | cr0Qoq_RTP-200A-SI-2-HS.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Warning: The status of this material is 'Commercial: Limited Issue' The data for this material has not been recently verified. Please contact RTP Company for current information prior to specifying this grade. |
General Information | |
---|---|
Additive |
|
Features |
|
RoHS Compliance |
|
Appearance |
|
Forms |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Specific Gravity | 1.13 | g/cm³ | ASTM D792 |
Molding Shrinkage - Flow (3.18 mm) | 1.3 | % | ASTM D955 |
Water Absorption (23°C, 24 hr) | 1.9 | % | ASTM D570 |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Rockwell Hardness (R-Scale) | 116 | ASTM D785 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus | 1860 | MPa | ASTM D638 |
Tensile Strength | 82.7 | MPa | ASTM D638 |
Tensile Elongation (Break) | 75 | % | ASTM D638 |
Flexural Modulus | 2070 | MPa | ASTM D790 |
Flexural Strength | 89.6 | MPa | ASTM D790 |
Compressive Strength | 68.9 | MPa | ASTM D695 |
Coefficient of Friction (With Metal-Dynamic) | 0.10 | ASTM D1894 |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Notched Izod Impact (3.18 mm) | 53 | J/m | ASTM D256 |
Unnotched Izod Impact (3.18 mm) | 850 | J/m | ASTM D4812 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Deflection Temperature Under Load | ASTM D648 | ||
0.45 MPa, not annealed | 171 | °C | ASTM D648 |
1.8 MPa, not annealed | 71.1 | °C | ASTM D648 |
CLTE - Flow | 8.3E-5 | cm/cm/°C | ASTM D696 |
Thermal Conductivity | 0.25 | W/m/K | ASTM C177 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Volume Resistivity | 1.0E+11 | ohms·cm | ASTM D257 |
Dielectric Strength | 16 | kV/mm | ASTM D149 |
Dielectric Constant (1 MHz) | 3.40 | ASTM D150 | |
Dissipation Factor (1 MHz) | 0.030 | ASTM D150 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flame Rating (1.59 mm, RTP Tested) | V-2 | UL 94 |
Additional Information |
---|
Mold Shrinkage, Linear-Flow, ASTM D-955, 0.25in.: 17mil/in.Wear Factor, K, ASTM D-3702: 50E-10in³/min/ft/lb/hrCoefficient of Friction, Dynamic, ASTM D-3702: 0.10The wear factor and dynamic coefficient of friction were both tested on a Falex Model No.6 Wear Testing Machine at 50 FPM, 2000 PV, against C1018 steel of hardness 15-25 Rockwell C, 14-17 micro smoothness. |
Injection | Nominal Value | Unit | |
---|---|---|---|
Rear Temperature | 232 - 260 | °C | |
Middle Temperature | 232 - 260 | °C | |
Front Temperature | 232 - 260 | °C | |
Mold Temperature | 65.6 - 93.3 | °C | |
Injection Pressure | 68.9 - 138 | MPa |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
SAXALAC™ 310T | SAX Polymers | ABS | SAXALAC™ |
SUSTAMID 6G | Röchling Sustaplast SE & Co. KG | Nylon 6 | SUSTAMID |
NILAMID® A3 J28 | Nilit Plastics | Nylon 66 | NILAMID® |
Braskem PE TN7006 | Braskem | LDPE | Braskem PE |
Celstran庐 PA66-GF50-20 AD3007 | Celanese Corporation | Nylon 66 | Celstran® |