Category: | TP, Unspecified , Thermoplastic |
Manufacturer: | Melos GmbH |
Trademark: | Mecoline |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | cVVKeg_Mecoline-IS-RDX-1231-F.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
It is an excellent choice for single core power cable for protected, fixed installation inside and outside railway vehicles for connecting fixed parts in direct current and alternating voltage technology, especially converter technology. The RDX 2264-3 compound is very low temperature resistant to -40°C and IRM 902 & IRM 903 oil resistant |
General Information | |
---|---|
Additive |
|
Features |
|
Uses |
|
Agency Ratings |
|
RoHS Compliance |
|
Forms |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density | 1.62 | g/cm³ | ISO 1183/A |
Melt Mass-Flow Rate (MFR) (175°C/21.6 kg) | 7.0 | g/10 min | ISO 1133 |
pH | > 4.5 | IEC 60754-2 | |
Shrinkage - 1h at 120°C | < 2.0 | % | IEC 811-1-3 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Hot Pressure Test - penetration 4h at 140°C | < 50 | % | DIN VDE 0472 |
Hot Set 1 | IEC 540 | ||
Elongation under load | < 40 | % | |
Residual elongation | < 10 | % | |
Temperature Index | 300 | °C | ASTM D2863 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Conductivity | < 4.00 | µS/mm |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Halogen Content | 0 | % | IEC 754-1 |
Toxicity | 2.00 | EN 50305 | |
Vertical Burn Test | < 540 | mm |
Extrusion | Nominal Value | Unit | |
---|---|---|---|
Head Temperature | 160 to 170 | °C | |
Extruder Screw L/D Ratio | >24.0:1.0 |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Shore Hardness (Shore A) | 85 | ISO 7619 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Stress | IEC 811-1-1 | ||
-- 2 | > 12.0 | MPa | |
-- 3 | > 9.00 | MPa | |
Tensile Strain | |||
Break 4 | > 180 | % | IEC 811-1-1 |
Break 5 | > 200 | % | IEC 811-1-1 |
Break, -40°C | > 35 | % | IEC 811-1-4 |
Aging | Nominal Value | Unit | Test Method |
---|---|---|---|
Change in Tensile Strength in Air (120°C, 240 hr) | < 25 | % | IEC 811-1-2 |
Change in Tensile Strain at Break in Air (120°C, 240 hr) | < 25 | % | IEC 811-1-2 |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Volume Resistivity (23°C) | > 1.0E+10 | ohms·cm | IEC 60093 |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Oxygen Index | 40 | % | ASTM D2863 |
Extrusion | Nominal Value | Unit | |
---|---|---|---|
Drying Temperature | 60.0 | °C | |
Drying Time | 4.0 | hr | |
Cylinder Zone 1 Temp. | 130 to 140 | °C | |
Cylinder Zone 2 Temp. | 150 to 160 | °C | |
Cylinder Zone 3 Temp. | 160 to 170 | °C | |
Cylinder Zone 4 Temp. | 160 to 170 | °C | |
Cylinder Zone 5 Temp. | 160 to 170 | °C | |
Adapter Temperature | 160 to 170 | °C | |
Die Temperature | 160 to 170 | °C |
Note Message | |
---|---|
1 . | at 200°C/15min/0.2 MPa |
2 . | After crosslinking |
3 . | Before crosslinking |
4 . | After crosslinking |
5 . | Before crosslinking |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
BULKSAM® TM-25M | UMG ABS, Ltd. | ABS | BULKSAM® |
KEBAFLOW® LCP MX130 | BARLOG plastics GmbH | LCP | KEBAFLOW® |
K-Bin Rigid PVC KB-7471 | K-Bin, Inc. | PVC, Rigid | K-Bin Rigid PVC |
LNP™ LUBRICOMP™ WI001 compound | SABIC Innovative Plastics Europe | PBT | LNP™ LUBRICOMP™ |