UBESTA 3030 JI9L

Category: Nylon 12 , Polyamide 12
Manufacturer: UBE Engineering Plastics, S.A.
Trademark: UBESTA
Fillers: -
Ports: Qinzhou, Shekou, Shanghai, Ningbo
Delivery Terms FOB, CIF, DAP, DAT, DDP
PDF: aqGW5S_UBESTA-3030-JI9L.pdf
PRICE: ​Order Products​ email   sales@su-jiao.com
Wechat: WECHAT
Message
UBESTA 3030 JI9L is a plasticized and impact modified PA12 grade for heat resistant airbrake tubing. The material is stabilized against weatherability. It is designed for high burst pressure performance at elevated temperatures as modern brake systems in trucks are operating at 12.5 bar.
General Information
Additive
  • Impact modifier
  • Plasticizer
Features
  • Impact modification
  • Plasticized
  • Impact resistance, high
  • Workability, good
  • Good weather resistance
  • Thermal stability, good
Uses
  • Pipe fittings
Agency Ratings
  • DIN 73378
Appearance
  • Black
Forms
  • Particle
Processing Method
  • Extrusion
PhysicalNominal ValueUnitTest Method
Density 1.02g/cm³ISO 1183
Melt Mass-Flow Rate (MFR) (235°C/2.16 kg)4.0g/10 minISO 1133
Molding Shrinkage ISO 294-4
    Vertical flow direction 1.4%ISO 294-4
    Flow direction 0.60%ISO 294-4
Water Absorption (23°C, 24 hr)0.70%ISO 62
HardnessNominal ValueUnitTest Method
Rockwell Hardness (R-Scale)71ISO 2039-2
Durometer Hardness (Shore D)70ISO 868
MechanicalNominal ValueUnitTest Method
Tensile Stress (Yield)30.0MPaISO 527-2
Tensile Strain ISO 527-2
    Yield 14%ISO 527-2
    Fracture 200%ISO 527-2
Flexural Modulus 500MPaISO 178
Flexural Stress 25.0MPaISO 178
ImpactNominal ValueUnitTest Method
Charpy Notched Impact Strength ISO 179/1eA
    -40°C, complete fracture 4.0kJ/m²ISO 179/1eA
    23°C, local fracture 90kJ/m²ISO 179/1eA
ThermalNominal ValueUnitTest Method
Heat Deflection Temperature
    0.45 MPa, not annealed 93.0°CISO 75-2/B
    1.8 MPa, not annealed 44.0°CISO 75-2/A
Melting Temperature (DSC) 175°CISO 3146
CLTE - Flow 1.6E-4cm/cm/°CISO 11359-2
ElectricalNominal ValueUnitTest Method
Volume Resistivity 1.0E+13ohms·cmIEC 60093
Additional Information
The value listed as Melting Temperature, ISO 3146, was tested in accordance with ISO 11357.Tensile Strain at Break, ISO 527: >200%Abrasion Loss, ISO 9352, CS-17, 1000 rev.: 7 mg
Resin Grade Manufacturer Category Trademark
RTP 2800-40D RTP Company TPO (POE) RTP
SureSpec HD60-70 Genesis Polymers HDPE SureSpec
TITANZEX® HI2200 Lotte Chemical Titan (M) Sdn. Bhd. HDPE TITANZEX®
NuSil CV3-2640 NuSil Technology Silicone NuSil
Akulon® F130-C2 DSM Engineering Plastics Nylon 6 Akulon®