Category: | PC , Polycarbonate Resin |
Manufacturer: | Trinseo |
Trademark: | CALIBRE™ |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | aC0Uwh_CALIBRE-2060-3.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
CALIBRE™ 2060-3 Polycarbonate resin is used in medical applications involving steam or ethylene oxide sterilization - though suitability for use in these applications is dependent upon autoclave cycle times and temperatures. CALIBRE 2060-3 provides exceptional clarity, heat resistance, impact strength and has low contamination levels. The CALIBRE 2000 series of resins have been evaluated with respect to ISO 10993-1 (Biological Evaluation of Medical Devices) and are suitable for use in approved medical applications. Main Characteristics
Applications
|
General Information | |
---|---|
Features |
|
Uses |
|
Agency Ratings |
|
Forms |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Specific Gravity | 1.20 | g/cm³ | ASTM D792, ISO 1183/B |
Melt Mass-Flow Rate (MFR) (300°C/1.2 kg) | 3.5 | g/10 min | ASTM D1238, ISO 1133 |
Molding Shrinkage - Flow | 0.50 to 0.70 | % | ASTM D955, ISO 294-4 |
Water Absorption | ASTM D570, ISO 62 | ||
23°C, 24 hr | 0.15 | % | |
Equilibrium, 23°C, 50% RH | 0.32 | % |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Rockwell Hardness | ASTM D785 | ||
M-Scale | 74 | ||
R-Scale | 118 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Modulus | |||
-- 1 | 2480 | MPa | ASTM D638 |
-- | 2480 | MPa | ISO 527-2/50 |
Tensile Strength | |||
Yield 2 | 60.0 | MPa | ASTM D638 |
Yield | 60.0 | MPa | ISO 527-2/50 |
Break 3 | 72.4 | MPa | ASTM D638 |
Break | 72.0 | MPa | ISO 527-2/50 |
Tensile Elongation | |||
Break 4 | 150 | % | ASTM D638 |
Break | 150 | % | ISO 527-2/50 |
Flexural Modulus | |||
-- 5 | 2410 | MPa | ASTM D790 |
-- 6 | 2410 | MPa | ISO 178 |
Flexural Strength | |||
-- 7 | 96.5 | MPa | ASTM D790 |
-- 8 | 96.0 | MPa | ISO 178 |
Taber Abrasion Resistance | 45 | % | ASTM D1044 |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Notched Izod Impact | |||
23°C | 960 | J/m | ASTM D256 |
23°C | 93 | kJ/m² | ISO 180/A |
Unnotched Izod Impact (23°C) | No Break | ASTM D256, ISO 180 | |
Instrumented Dart Impact (23°C, Total energy) | 93.8 | J | ASTM D3763 |
Tensile Impact Strength | 630 | kJ/m² | ASTM D1822 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Deflection Temperature Under Load | |||
0.45 MPa, Annealed | 146 | °C | ASTM D648, ISO 75-2/B |
1.8 MPa, Unannealed | 132 | °C | ASTM D648, ISO 75-2/A |
1.8 MPa, Annealed | 143 | °C | ASTM D648, ISO 75-2/A |
Vicat Softening Temperature | 151 | °C | ISO 306/B50, ASTM D1525 9 |
CLTE - Flow (-40 to 82°C) | 6.8E-5 | cm/cm/°C | ASTM D696 |
Optical | Nominal Value | Unit | Test Method |
---|---|---|---|
Refractive Index | 1.586 | ASTM D542, ISO 489 | |
Transmittance 10(3180 µm) | 89.0 | % | ASTM D1003 |
Haze 11(3180 µm) | 1.0 | % | ASTM D1003 |
Note Message | |
---|---|
1 . | 50 mm/min |
2 . | 50 mm/min |
3 . | 50 mm/min |
4 . | 50 mm/min |
5 . | Method I (3 point load), 2.0 mm/min |
6 . | 2.0 mm/min |
7 . | Method I (3 point load), 2.0 mm/min |
8 . | 2.0 mm/min |
9 . | Rate A (50°C/h), Loading 2 (50 N) |
10 . | 1/8 inch thickness plaque |
11 . | 1/8 inch thickness plaque |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
PROTEQ™ C16ST8 | Marplex Australia Pty. Ltd. | PP Copolymer | PROTEQ™ |
SLOVALEN® PH 99 GF 15 TS | Plastcom | PP, Unspecified | SLOVALEN® |
NEFTEKHIM PP 1362R (Z21S) | Nizhnekamskneftekhim Inc. | PP Homopolymer | NEFTEKHIM PP |
Crastin® HR5330HF NC010 | DuPont Performance Polymers | PBT | Crastin® |
Dugdale PVC Rigid Bottle Compound | Dugdale Plc | PVC, Rigid | Dugdale PVC |