Category: | PPS , Polyphenylene Sulfide |
Manufacturer: | Solvay Specialty Polymers |
Trademark: | Ryton® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | X7K0XC_Ryton-R-7-120NA.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Ryton® R-7-120NA and R-7-120BL glass fiber and mineral filled polyphenylene sulfide compounds provide good strength and low maintenance molding using conventional molding equipment. |
General Information | |
---|---|
Filler / Reinforcement |
|
Features |
|
Uses |
|
RoHS Compliance |
|
Appearance |
|
Forms |
|
Processing Method |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Specific Gravity | 1.99 | g/cm³ | ASTM D792 |
Molding Shrinkage | |||
Flow : 3.20 mm | 0.20 | % | |
Across Flow : 3.20 mm | 0.40 | % | |
Water Absorption (23°C, 24 hr) | 0.020 | % | ASTM D570 |
Hardness | Nominal Value | Unit | Test Method |
---|---|---|---|
Rockwell Hardness | ASTM D785 | ||
M-Scale | 101 | ||
R-Scale | 118 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Tensile Strength | |||
-- | 131 | MPa | ASTM D638 |
-- | 140 | MPa | ISO 527-2 |
Tensile Elongation (Break) | 0.90 | % | ASTM D638, ISO 527-2 |
Flexural Modulus | |||
-- | 19300 | MPa | ASTM D790 |
-- | 19000 | MPa | ISO 178 |
Flexural Strength | |||
-- | 207 | MPa | ASTM D790 |
-- | 220 | MPa | ISO 178 |
Compressive Strength | 265 | MPa | ASTM D695 |
Poisson's Ratio | 0.36 | ISO 527 |
Impact | Nominal Value | Unit | Test Method |
---|---|---|---|
Notched Izod Impact | |||
3.18 mm | 59 | J/m | ASTM D256 |
-- | 6.0 | kJ/m² | ISO 180/A |
Unnotched Izod Impact | |||
3.18 mm | 210 | J/m | ASTM D4812 |
-- | 15 | kJ/m² | ISO 180 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Deflection Temperature Under Load (1.8 MPa, Unannealed) | 265 | °C | ASTM D648 |
CLTE | ASTM E831 | ||
Flow : -50 to 50°C | 1.5E-5 | cm/cm/°C | |
Flow : 100 to 200°C | 1.5E-5 | cm/cm/°C | |
Transverse : -50 to 50°C | 3.0E-5 | cm/cm/°C | |
Transverse : 100 to 200°C | 7.0E-5 | cm/cm/°C | |
Thermal Conductivity | 0.59 | W/m/K | |
UL Temperature Rating | 220 to 240 | °C | UL 746B |
Electrical | Nominal Value | Unit | Test Method |
---|---|---|---|
Surface Resistivity | 1.0E+16 | ohms | ASTM D257 |
Volume Resistivity | 1.0E+15 | ohms·cm | ASTM D257 |
Dielectric Strength | 16 | kV/mm | ASTM D149 |
Dielectric Constant | ASTM D150 | ||
25°C, 1 kHz | 4.90 | ||
25°C, 1 MHz | 4.90 | ||
Dissipation Factor | ASTM D150 | ||
25°C, 1 kHz | 4.0E-3 | ||
25°C, 1 MHz | 2.0E-3 | ||
Arc Resistance | 185 | sec | ASTM D495 |
Comparative Tracking Index (CTI) | 250 | V | UL 746 |
Insulation Resistance 1(90°C) | 1.0E+11 | ohms |
Flammability | Nominal Value | Unit | Test Method |
---|---|---|---|
Flame Rating (1.60 mm) | V-0 5VA | UL 94 | |
Oxygen Index | 61 | % | ASTM D2863 |
Note Message | |
---|---|
1 . | 95%RH, 48 hr |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
ACCUTECH™ HP0339G40CL | ACLO Compounders Inc. | PP Homopolymer | ACCUTECH™ |
Dorlyl PVC GFE 75A | DORLYL S.N.C. | PVC, Unspecified | Dorlyl PVC |
Hostacom EKC 325 N | LyondellBasell Industries | PP Impact Copolymer | Hostacom |
Plaslube® PC / PET IM 1016 UV | Techmer Engineered Solutions | PC+PET | Plaslube® |
Optix® CA-51 LL | Plaskolite, Inc. | Acrylic (PMMA) | Optix® |