35% Glass Reinforced, Toughened, PPA, High Performance Polyamide
General Information
Filler / Reinforcement
  • Glass Fiber, 35% Filler by Weight
Additive
  • Heat Stabilizer
Features
  • Heat Stabilized
Agency Ratings
  • UL Unspecified Rating
Processing Method
  • Injection Molding
Multi-Point Data
  • Isothermal Stress vs. Strain (ISO 11403-1)
  • Secant Modulus vs. Strain (ISO 11403-1)
  • Tensile Modulus vs. Temperature (ISO 11403-1)
Part Marking Code (ISO 11469)
  • >PA-IGF35<
Part Marking Code (SAE J1344)
  • >PPA-IGF35<
PhysicalDryConditionedUnitTest Method
Density 1.42--g/cm³ISO 1183
Molding Shrinkage ISO 294-4
     Across Flow 0.50--%
     Flow 0.20--%
MechanicalDryConditionedUnitTest Method
Tensile Modulus 1050010800MPaISO 527-2
Tensile Stress (Break)180166MPaISO 527-2
Tensile Strain (Break)3.02.7%ISO 527-2
Flexural Modulus 93009500MPaISO 178
Flexural Stress 280--MPaISO 178
ImpactDryConditionedUnitTest Method
Charpy Notched Impact Strength ISO 179/1eA
     -40°C 9.09.0kJ/m²
     -30°C 109.0kJ/m²
     23°C 1211kJ/m²
Charpy Unnotched Impact Strength ISO 179/1eU
     -40°C 7565kJ/m²
     23°C 8570kJ/m²
Notched Izod Impact Strength (23°C)12--kJ/m²ISO 180/1A
ThermalDryConditionedUnitTest Method
Heat Deflection Temperature
     0.45 MPa, Unannealed 283--°CISO 75-2/B
     1.8 MPa, Unannealed 255--°CISO 75-2/A
Melting Temperature 1300--°CISO 11357-3
CLTE ISO 11359-2
     Flow 2.0E-5--cm/cm/°C
     Flow : -40 to 23°C 2.0E-5--cm/cm/°C
     Transverse 6.8E-5--cm/cm/°C
     Transverse : -40 to 23°C 6.5E-5--cm/cm/°C
ElectricalDryConditionedUnitTest Method
Volume Resistivity 1.0E+15--ohms·cmIEC 60093
Electric Strength 4342kV/mmIEC 60243-1
Comparative Tracking Index 600--VIEC 60112
FlammabilityDryConditionedUnitTest Method
Flammability Classification IEC 60695-11-10, -20
     0.750 mm HB--
     1.50 mm HB--
Note Message
1 .First Heat
Resin Grade Manufacturer Category Trademark
WELLAMID Nylon 6000/52 GV 15 HWCP CP-Polymer-Technik GmbH & Co. KG Nylon 6 WELLAMID Nylon
BR® 623P4 Cytec Industries Inc. Epoxy BR®
BULKSAM® MG-2520A UMG ABS, Ltd. ABS BULKSAM®
Cri-Line FKHT-717 Cri-Tech, Inc. Fluorelastomer Cri-Line
Lionpol IM-40093 Lion Polymers Incorporated TPE Lionpol