Category: | Nylon 6 , Polyamide 6 |
Manufacturer: | BASF Corporation |
Trademark: | Ultramid® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | SXagco_Ultramid-B3UM4.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Mineral reinforced, halogen- and phosphorus free flame retardant injection moulding grade. |
General Information | |
---|---|
Filler / Reinforcement |
|
Additive |
|
Features |
|
Agency Ratings |
|
RoHS Compliance |
|
Forms |
|
Processing Method |
|
Resin ID (ISO 1043) |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density | 1.35 | -- | g/cm³ | ISO 1183 |
Apparent Density | 0.70 | -- | g/cm³ | |
Melt Volume-Flow Rate (MVR) (275°C/5.0 kg) | 90.0 | -- | cm³/10min | ISO 1133 |
Water Absorption (Equilibrium, 23°C, 50% RH) | 2.0 to 2.4 | -- | % | ISO 62 |
Mold Shrinkage - Test box (1.50 mm) | 0.60 | -- | % |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Fire Performance - UL94+HAI+HWI 1 | > 3.00 | -- | mm | UL 746C |
Additional Information | Dry | Conditioned | Test Method | |
---|---|---|---|---|
Hot Wire Test (3.0 µm) | 1.00 | -- | ASTM D3874 |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Modulus | 5300 | 1800 | MPa | ISO 527-2 |
Tensile Stress (Yield) | 70.0 | 30.0 | MPa | ISO 527-2 |
Tensile Strain (Break) | 3.0 | 50 | % | ISO 527-2 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Unnotched Impact Strength | 40 | 200 | kJ/m² | ISO 179/1eU |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature (1.8 MPa, Unannealed) | 110 | -- | °C | ISO 75-2/A |
Melting Temperature (DSC) | 220 | -- | °C | ISO 3146 |
Electrical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Comparative Tracking Index (Solution A) | 600 | -- | V | IEC 60112 |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Flame Rating (> 0.750 mm) | V-2 | -- | UL 94 | |
Glow Wire Flammability Index (1.50 mm) | 960 | -- | °C | IEC 60695-2-12 |
Oxygen Index | 32 | -- | % | ISO 4589-2 |
Note Message | |
---|---|
1 . | For Electrical Insulation/Barrier with close proximity (< 0,8 mm) to uninsulated live parts according to UL 746C |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Radilon® S USZ200 100 NAT | Radici Plastics | Nylon 6 | Radilon® |
Ad-Tech Polyester NO. 19A | Ad-Tech Plastic Systems Corp. | Polyester, TS | Ad-Tech Polyester |
Forprene® 6SD001A55 | SO.F.TER. SPA | TPV | Forprene® |
OTECH PVC PL1001-3 - Plenum Jacket | OTECH Corporation | PVC, Unspecified | OTECH PVC |
Edgetek™ ET6000-5009 NHFR White VN-3902 | PolyOne Corporation | Nylon 6 | Edgetek™ |