Category: | Nylon 66 , Polyamide 66 |
Manufacturer: | Polykemi AB |
Trademark: | SCANAMID 66 |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | NW00yD_SCANAMID-66-A12-F20.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Glass fibre reinforced |
General Information | |
---|---|
Filler / Reinforcement |
|
Physical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Density | 1.27 | -- | g/cm³ | ISO 1183 |
Molding Shrinkage | ISO 294-4 | |||
Across Flow | 1.2 | -- | % | |
Flow | 0.40 | -- | % |
Mechanical | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Tensile Stress | 140 | 125 | MPa | ISO 527-2 |
Tensile Strain (Yield) | 4.0 | 6.0 | % | ISO 527-2 |
Flexural Modulus (23°C) | 6800 | 4200 | MPa | ISO 178 |
Flexural Stress | 200 | 120 | MPa | ISO 178 |
Impact | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Charpy Notched Impact Strength | ISO 179 | |||
-20°C | -- | 6.0 | kJ/m² | |
23°C | 8.0 | 11 | kJ/m² |
Thermal | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Heat Deflection Temperature 1 | ||||
0.45 MPa, Unannealed | 250 | -- | °C | ISO 75-2/B |
1.8 MPa, Unannealed | 245 | -- | °C | ISO 75-2/A |
Vicat Softening Temperature | > 230 | -- | °C | ISO 306/B50 |
Flammability | Dry | Conditioned | Unit | Test Method |
---|---|---|---|---|
Flame Rating (1.60 mm) | HB | -- | UL 94 | |
Glow Wire Ignition Temperature (2.00 mm) | 650 | -- | °C | IEC 60695-2-13 |
Note Message | |
---|---|
1 . | 120°C/hr |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
Sylvin 8308-60 Natural | Sylvin Technologies Incorporated | PVC, Flexible | Sylvin |
Sylvin 8280-65 Natural | Sylvin Technologies Incorporated | PVC, Flexible | Sylvin |
Veradel® A-304P | Solvay Specialty Polymers | PESU | Veradel® |
Toraycon® 5174G-X11 | Toray Resin Company | PBT | Toraycon® |
WELLAMID Nylon 6000/42 GV 15 HWUVCP | CP-Polymer-Technik GmbH & Co. KG | Nylon 6 | WELLAMID Nylon |