Category: | Nylon 6 , Polyamide 6 |
Manufacturer: | DSM Engineering Plastics |
Trademark: | Akulon® |
Fillers: | - |
Ports: | Qinzhou, Shekou, Shanghai, Ningbo |
Delivery Terms | FOB, CIF, DAP, DAT, DDP |
PDF: | Dq7UwT_Akulon-F130.pdf ![]() |
PRICE: | Order Products email sales@su-jiao.com |
Message |
---|
Akulon®F130 is a polyamide 6 (nylon 6) material,. This product is available in Europe and is processed by film extrusion or extrusion. Akulon®The main characteristics of F130 are: medium viscosity. |
General Information | |
---|---|
Features |
|
Forms |
|
Processing Method |
|
Multi-Point Data |
|
Physical | Nominal Value | Unit | Test Method |
---|---|---|---|
Density | 1.13 | g/cm³ | ISO 1183 |
Viscosity Number | 196 | cm³/g | ISO 307 |
Mechanical | Nominal Value | Unit | Test Method |
---|---|---|---|
Coefficient of Friction | ISO 8295 | ||
With itself-dynamic, cast film | 1.0 | ISO 8295 | |
With itself-static, cast film | 1.5 | ISO 8295 |
Films | Nominal Value | Unit | Test Method |
---|---|---|---|
Film Thickness - Tested | 50 | µm | |
Tensile Modulus 1(50 µm, Cast Film) | 455 | MPa | Internal method |
Tensile Stress - MD | ISO 527-3 | ||
Yield, 50 µm, cast film | 31.0 | MPa | ISO 527-3 |
50 µm, cast film | 82.0 | MPa | ISO 527-3 |
Tensile Elongation - MD (Broken, 50 µm, cast film) | 350 | % | ISO 527-3 |
Trouser Tear Resistance - MD (50 µm, Cast Film) | 32.0 | N/mm | ISO 6383-1 |
Water Vapor Transmission Rate (23°C, 85% RH, 50 µm, cast film) | 35 | g/m²/24 hr | DIS 15106-1/-3 |
Oxygen Transmission Rate 2 | DIS 15105-1/-2 | ||
0% RH : 23°C, 50.0 µm | 26 | cm³/m²/bar/24 hr | DIS 15105-1/-2 |
85% RH : 23°C, 50.0 µm | 39 | cm³/m²/bar/24 hr | DIS 15105-1/-2 |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
Specific Heat Capacity | |||
-- | 1550 | J/kg/°C | |
Average : 20 to 150°C | 2250 | J/kg/°C |
Additional Information | Nominal Value | Unit | Test Method |
---|---|---|---|
Puncture Resistance (50.0 µm) 3 | 13.0 | J/cm | Internal method |
RSV - Formic Acid, 1g/100 ml | 3.03 | Internal method |
Thermal | Nominal Value | Unit | Test Method |
---|---|---|---|
CLTE - Flow | 9.0E-5 | cm/cm/°C | ISO 11359-2 |
Optical | Nominal Value | Unit | Test Method |
---|---|---|---|
Transmittance (50.0 µm, Cast Film) | 83.0 | % | Internal method |
Fill Analysis | Nominal Value | Unit | Test Method |
---|---|---|---|
Melt Viscosity (260°C) | 810 | Pa·s | Internal method |
Additional Information | Nominal Value | Unit | Test Method |
---|---|---|---|
Processing parameters for cast film test specimen: Extruder Temperature: 270°C Die Temperature: 270°C Chill Roll Temperature: 110°C |
Note Message | |
---|---|
1 . | 50 mm/min |
2 . | Cast Film |
3 . | Cast Film |
Resin Grade | Manufacturer | Category | Trademark |
---|---|---|---|
VAMPAMID 6 1026 V0 DF | Vamp Tech | Nylon 6 | VAMPAMID |
ACCUTECH™ HP0334G5M25CL | ACLO Compounders Inc. | PP Homopolymer | ACCUTECH™ |
AKROTEK® PK-HM natural (4773) | AKRO-PLASTIC GmbH | PK-Aliphatic | AKROTEK® |
Cheng Yu B600 | Cheng Yu Plastic Company Limited | PC+PBT | Cheng Yu |
Generic PEEK | Generic | PEEK | Generic |