Dow ENDURANCE™ HFDA-0693 BK LS

Category: TP, Unspecified , Strippable Semiconductive Insulation Shielding Compound
Manufacturer: The Dow Chemical Company
Trademark: Dow ENDURANCE™
Fillers: -
Ports: Qinzhou, Shekou, Shanghai, Ningbo
Delivery Terms FOB, CIF, DAP, DAT, DDP
PDF: DDBRDU_Dow-ENDURANCE-HFDA-0693-BK-LS.pdf
PRICE: ​Order Products​ email   sales@su-jiao.com
Wechat: WECHAT
Message
DOW ENDURANCE™ HFDA-0693 BK LS is specially formulated semiconductive, vulcanizable compound designed for use in conventional extrusion practices as a strippable insulation shield for medium voltage power cable. DOW ENDURANCE™ HFDA-0693 BK LS was designed to have excellent extrusion processing. DOW ENDURANCE™ HFDA-0693 BK LS is an easy stripping insulation shield recommended for use over DOW ENDURANCE™ crosslinked polyethylene compounds. This product provides low strip force over a wide temperature range when used in conjunction with Dow insulation materials.

Specifications:
DOW ENDURANCE™ HFDA-0693 BK LS is designed for use in power distribution cables. Cables with conductor and insulation shielding of DOW ENDURANCE™ HFDA-0693 BK LS, prepared using sound commercial fabrication practice, would be expected to meet the following specifications:
  • ANSI/ICEA: S-94-649, S-97-682, S-93-639 / NEMA WC74
  • AEIC: CS 8
  • IEC 60502
General Information
Uses
  • Medium Voltage Semiconductive Shield
  • Semiconductive Shield
  • Underground cable
  • Cable guard
  • Wire and cable applications
Agency Ratings
  • AEIC CS8
  • ICEA S-93-639
  • ICEA S-94-649
  • ICEA S-97-682
  • IEC 60502
  • NEMA WC-74
Forms
  • Particle
PhysicalNominal ValueUnitTest Method
Density 1.18g/cm³ASTM D1505
MechanicalNominal ValueUnitTest Method
Tensile Strength ASTM D638
    Fracture 14.5MPaASTM D638
    Fracture, 136°C 113.8MPaASTM D638
Tensile Elongation ASTM D638
    Fracture 280%ASTM D638
    Fracture, 136°C 2150%ASTM D638
ThermalNominal ValueUnitTest Method
Brittleness Temperature < -40.0°CASTM D746
ElectricalNominal ValueUnitTest Method
Volume Resistivity
    23°C 31.0E+2 - 4.0E+2ohms·cmS-66-524
    23°C 425ohms·cmASTM D991
    90°C 51.0E+2 - 4.0E+2ohms·cmS-66-524
    90°C 630ohms·cmASTM D991
    110°C 71.0E+2 - 4.0E+2ohms·cmS-66-524
    110°C 830ohms·cmASTM D991
Additional InformationNominal ValueUnitTest Method
Cable Adhesion Force - Dry Cure 9(23°C)2.1 - 4.2kN/mInternal method
ExtrusionNominal ValueUnit
Feed part of extruder 43 - 60°C
Additional InformationNominal ValueUnitTest Method
Nominal property values above represent tests on molded stress-relieved slabs. Cure times were 15 minutes at 175°C.Storage The environment or conditions of storage greatly influences the recommended storage time. Storage should be in accordance with good manufacturing practices. If proper warehousing and storage temperatures [dry conditions, between 50°F and 75°F (10°C and 23°C) in temperature] are utilized, this product may be stored by the customer for up to one year. It is recommended that the practice of using the product on a first-in / first-out basis be established. Storage under extreme conditions may affect the quality, processing, or performance of the product. Storage at elevated temperatures should be avoided to prevent blocking. Pellets are readily friable should blocking be experienced.
ExtrusionNominal ValueUnit
Cylinder Zone 1 Temp. 82.2 - 87.8°C
Cylinder Zone 2 Temp. 93.3 - 98.9°C
Cylinder Zone 3 Temp. 98.9 - 110°C
Cylinder Zone 4 Temp. 104 - 110°C
Cylinder Zone 5 Temp. 107 - 110°C
Melt Temperature 115 - 125°C
Extrusion instructions
DOW ENDURANCE™ HFDA-0693 BK LS provides excellent surface finish and outstanding output rates over a broad range of conditions. For optimum results, use melt extrusion temperatures in the suggested range of 235 to 255°F (115 to 125°C) to avoid pre-cure or scorch. Extruder barrel settings of 110°C (230°F) are suggested as a starting point while learning to process DOW ENDURANCE™ HFDA-0693 BK LS. Specific machine settings will depend on the extruder design and must be established through conventional practices. The curing temperature should be carefully controlled, and the maximum surface temperature in the CV tube should not exceed 527°F (275°C) for optimum results. Extruder feed-throat cooling is recommended to improve feed efficiency.DOW ENDURANCE™ HFDA-0693 BK LS can be handled in the same fashion as other vulcanizable polyolefin semiconductive materials. It is available in regular or UNICLEAN™ boxes and can be air-conveyed at transport temperatures of 75°F (24°C) or below. Do not use a heated dryer with HFDA-0693 BK as pellets may fuse. During shutdowns exceeding one hour, DOW ENDURANCE™ HFDA-0693 BK LS pellets should be removed from potentially warm hopper bins to avoid fusing.
Note Message
1 .1 week
2 .1 week
3 .on cables
4 .on plaques
5 .on cables
6 .on plaques
7 .on cables
8 .on plaques
9 .Cable adhesion values are typical for dry cure at room temperature. Values will vary with cable size, insulation type, type of cure, temperature, speed of test, etc.
Resin Grade Manufacturer Category Trademark
Spartech Polycom SCR7-7010RF Spartech Polycom PC Spartech
DOW™ LDPE 993I The Dow Chemical Company LDPE DOW™ LDPE
DENILEN B 4010 CB WT Vamp Tech PP, Unspecified DENILEN
Generic PP Alloy - Mineral Generic PP Alloy Generic
KOPLA PC KCG1020F KOPLA Co., Ltd. PC KOPLA PC